ABSTRACT
Objectives:
to evaluate the efficacy and safety of transobturator tape in the treatment of female stress urinary incontinence (SUI). To assess the level of satisfaction with the technique.
Methods:
prospective study. Population: 60 patients who underwent TOT procedure from February 2002 to October 2004. Patients were assessed in five temporary sections, up to February 2011. Inclusion criteria: incontinence as a subjective symptom, stress incontinence on physical examination and urodynamic test that confirmed it. Technique: recyclable needles and simple polypropylene mesh instead of commercials kits.
Results:
no vascular, nervous, neither digestive injury was registered. One case of bladder injury. Primary outcomes: 56,7% of the patients are asymptomatic, 25% better and 18,3% do not refer changes. 71,7% are very satisfied, 13,3% mild satisfied and 13,3% unsatisfied.
Conclusions:
the results confirm the effectiveness of TOT in treating female SUI with a low complication rate. The effectiveness of the technique decreases with time.